Analisis Tingkat Pencemaran Air Sungai Krueng Tamiang Terhadap COD, BOD dan TSS

Bahagia Bahagia, Suhendrayatna Suhendrayatna, Zulkifli Ak

Abstract


Industrial waste is a factor influencing the pollution of the Krueng Tamiang river. The purpose of this study was to analyze the level of water pollution in the Krueng Tamiang river with the parameters of Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) and Total suspended Solid (TSS) parameters. The results showed the highest BOD parameter test results came from location 2 (Seumadam Bridge) of 3.63 mg / L at stage IV and the lowest BOD value at locations 1 and 6 (Kaloy Village and Alur Manis Bridge) at stage I of 2 mg / L. The highest COD parameter test results came from location 5 (Kota Lintang Bridge) of 21.0 mg / L at stage III and the lowest COD value at location location 1 (Kaloy Village) at stage III, points 1, 3 and 6 (Kaloy Village, Kebon Tengah Suspension Bridge and Alur Manis Bridge) at stage IV of 17.0 mg / L. The highest TSS parameter test results came from location 7 (Peukan Seuruway), namely 295 mg / L phase I in the dry season, and the lowest TSS value at location 1 (Kaloy Village), which was 11 mg / L in stage III during the rainy season.

Keywords


Pollution, water discharge, river, waste disposal, excavation C, BOD, COD and TSS.

Full Text:

PDF

References


Arsyad. S, Konservasi Tanah dan Air, Edisi Kedua, IPB Press, Bogor, 2010.

Elna Soukotta, Robert Ozsaer, Bokiraya Latuamury, Analisis Kualitas Kimia Air Sungai Riuapa dan Dampaknya Terhadap Lingkungan, Jurnal Hutan Pulau-Pulau Kecil, 2019

Kristanto. P, Ekologi Industri, Penerbit Andi, Yogyakarta, 2004.

Azis Husen, Analisis Kualitas Air Sungai Yang Bermuara di Perairan Teluk Kao Halmahera Utara, Agrikan: Jurnal Agribisnis Perikanan, 2016.

Fatimah, S., Rahmiati. & Yoskasih. Jurnal Kimia. 3, 14-22, Program Studi Ilmu Kimia Fakultas MIPA Universitas Islam Indonesia, Slemen Yogyakarta, 2009.

Bayu Wiyantoko, Noor Rahmadani, Puji Kurniawati, Tri Esti Purbaningtias, Method verification of chemical oxygen demand (COD) and total suspended solid (TSS) analysis from Mentaya River, AIP Publishing, 2020.

Pazstor I., P. Thury, and J. Pulai, Chemical oxygen demand fractions of municipal wastewater for modelingof wastewater treatment University of Pannonia, Veszprem, Hungary. Journal Environment, Vol. 6(1) 51-56.ISSN: 1735-1472, 2009.

Gabriel. J. F, Fisika Lingkungan, Penerbit Hipokrates, Jakarta, 2001.

Asdak. Chay, Hidrologi dan Pengelolaan Daerah Aliran Sungai, Gajah Mada University Press, Yogyakarta, 2002.

Standar Nasional Indonesia (SNI) 6989. 57-2008, Metode Pengambilan Contoh Uji Kualitas Air Standar Nasional Indonesia, Badan Standarisasi Nasional, Bandung.

Bapedalda Aceh, Hasil Pengukuran Debit Sungai Krueng Tamiang Tahun 2015.

Dinas Lingkungan Hidup dan Kehutanan Aceh, Hasil Pengukuran Debit Sungai Krueng Tamiang Tahun 2016.

Dinas Lingkungan Hidup dan Kehutanan Aceh, Hasil Pengukuran Debit Sungai Krueng Tamiang Tahun 2017.

Suhendrayatna, Teknologi Pengelolahan Limbah B3, Jurusan Teknik Kimia Universitas Syiah Kuala, Darussalam, Banda Aceh, 2008.

Republik Indonesia, Peraturan Pemerintah Republik Indonesia Nomor 82 Tahun 2001 Tentang Pengelolaan Kualitas Air Dan Pengendalian Pencemaran Air

Suhendrayatna, Teknologi Pengelolahan Limbah B3, Jurusan Teknik Kimia Universitas Syiah Kuala, Darussalam, Banda Aceh, 2008.

Suhendrayatna, Teknologi Pengelolahan Limbah B3, Jurusan Teknik Kimia Universitas Syiah Kuala, Darussalam, Banda Aceh, 2008.

Republik Indonesia, Peraturan Pemerintah (PP) Nomor 82 Tahun 2001 Tentang Pengelolaan Kualitas Air dan Pengendalian Pencemaran Air.




DOI: https://doi.org/10.32672/jse.v5i3.2073